Features and Benefits
- FN3287 and FN3288 series of filters provides state-of-the-art EMI attenuation based on an innovative filter topology. They help to ensure compliance with Class C2 or even C1 limits.
- The slim book-style shape allows a convenient and space-saving installation next to inverters, converters or motor drives.
- The compact FN3287 and FN3288 filter from 10 to 230A are designed for the most diverse applications worldwide, including machinery and machine tools.
- FN3288HV filters up to 230 A are applicable for 690 VAC distribution networks.
- FN 3288IT and FN 3288HVIT filters up to 230 A meet the special requirements for IT distribution networks.
- Low leakage current filter versions help to fulfill tough requirements (e.g. 0.1 mA) in respect of leakage current limitation.
Typical Applications
- Three-phase variable speed drives and power drive systems (PDS)
- Machine tool and machinery equipment
- IT power distribution networks (FN3288IT and FN3288 HVIT)
- General energy conversion devices (inverters, converters)
- Process automation equipment
- Three-phase power supplies
- Low-leakage current requirements
Technical Specifications
Maximum continuous operating voltage
3×530/305 VAC (FN3287, FN3288)
3×530 VAC (FN3288IT)
3×760/440 VAC (FN3288HV)
3×760 VAC (FN3288HVIT)
Nominal operating voltage
480 VAC (FN3287, FN3288, FN3288IT)
690 VAC (FN3288HV, FN3288HVIT)
Rated currents
10 to 230 A
10 to 230 A @ 50°C
Overload capability
6x rated current for 1 sec, once per hour
1.5x rated current for 1 minute, once per hour
Operating frequency
DC to 60 Hz
High potential test voltage
P -> E 2260 VDC for 2 s (FN3287, FN3288)
P -> E 2900 VDC for 2 s (FN3288IT)
P -> P 2280 VDC for 2 s (FN3287, FN3288, FN3288IT)
P -> E 2650 VDC for 2 s (FN3288HV)
P -> E 3530 VDC for 2 s (FN3288HVIT)
P -> P 3270 VDC for 2 s (FN3288HV)
Overvoltage category
III acc. IEC 60664-1
Pollution degree
3 acc. IEC 60664-1
Temperature range (operation and storage)
-40°C to +100°C (with current derating >50°C)
Climatic category
40/100/21 acc. to IEC 60068-1
Protection category
IP 20 acc. to IEC 60529
Flammability corresponding to
UL 94 V-0
Vibration and shock
3M4 (operation)
2M2 (transport) acc. to IEC 60721-3-3
IEC 60721-3-2
Design corresponding to
UL 60939-3, IEC 60939-3
SCCR**
100 kA acc. to UL508 – high fault current
Compliance with insulation requirement
> 1MOhm acc. to IEC 60204-1
MTBF (Mil-HB-217F)
>200,000 h @ 50°C/480 V