Mircom’s FA-1008KADS Fire Alarm Control Unit is a microprocessor based unit designed for maximum flexibility and easy installation. Fully configurable from the front panel using the push buttons and DIP switches, it enables the user to configure the system to meet their specific requirements.
The FA-1008KADS consists of one MCC-1024-6ADS Main Chassis in a UB-1024DS back box with a DOX1024DS door. The MCC-1024-6ADS Main Chassis comes complete with 8 Class B (Style B) Initiating Circuits which may be configured as 4 Class A (Style D) Circuits. It can be expanded up to 24 Class B or 12 Class A circuits with the addition of the DM1008A Initiating Circuit Module. In addition it comes equipped with 4 Class A/B (Style Z/Y) Indicating circuits which are each rated at 1.7 Amps. The Main Chassis also includes a 6 Amp Power Supply which powers the system and supplies two 4-wire resettable regulated smoke power supply of 24 VDC 200mA maximum each.
The MCC-1024-6ADS also allows for the addition of two SGM-1004A Signal Modules or two RM-1008A Relay modules in place of the DM-1008A Initiating Circuit Adder Modules. (Maximum of 3 Adder modules) The backbox provides space for up to 18 AH Gel Cell batteries.
Features
• Listed to UL 864, 9th edition
• 8 Class B (Style B) Initiating Circuits which may be configured as 4 Class A (Style D) Circuits. Expandable up to 24 Class B or 12 Class A Initiating Circuits
• 4 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.7 Amps max. per circuit)
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audibles may be configured as Steady, Temporal Code, California Code or March Time
• Each Initiating Circuit can be configured as Alarm, Supervisory, Waterflow or Trouble
• Two LEDs per Initiating circuit; one for Trouble and one for Status
• Initiating and Indicating Circuits may be individually disconnected by a DIP switch
• Configurable Signal Silence Inhibit, Auto Signal Silence, Two-Stage Operation and One Man Walk Test
• Alarm Verification on Initiating Circuits • Subsequent Alarm, Supervisory and Trouble operation
• Two outputs for 4 wire resettable smoke power supply (200 mA Max. each)
• Auxiliary relay contacts for Common Alarm and Common Supervisory as well as a Common Trouble Relay (Each relay contact Form C, 28VDC @ 1 Amp (resistive))
• RS-485 Interface for RA-1000 Remote Multiplex Annunciators
• Interface for Remote Trouble Indicator
• Easy configuration via push buttons and DIP switches on the front panel
• Extensive Transient Protection
• 6 Amp Power Supply